FiberTite, Seaman Corporation

Roofing Systems

CONTACT INFO
1000 Venture Boulevard
Wooster, OH 44691-9360
Toll Free: 800-927-8578
Phone: 330-262-1111
Continuing Education Logo
Request for information FiberTite, Seaman Corporation Contact Us / RFI
SOCIAL

Green Vegetative Roofing System  

FTG-DAED1 - Ballast Rock at Drain with Edger
download: view:
FTG-DAEM1 - 4.5 inch Aluminum Edger at Multilayer
download: view:
FTG-DAEW1 - Ballast Rock at Wall with Edger
download: view:
FTG-DEML1 - Extensive Multilayer System
download: view:
FTG-DSML1 - Standard Multilayer System
download: view:
FTG-DSML2 - Standard Multilayer System with Vector Mapping Mesh
download: view:
FTG-DTBP1 - FTGVRS Tray System with Ballast Rock at Penetration
download: view:
FTG-DTBW1 - FTGVRS Tray System with Ballast Rock Walkway
download: view:
FTG-DTPW1 - FTGVRS Tray System with Concrete Paver Walkway
download: view:
FTG-DTRAY-A - Typical FTGVRS Tray Layout (Ballast)
download: view:
FTG-DTRAY-B - Typical FTGVRS Tray Layout (Pavers)
download: view:
FTG-DTRAY1 - Typical FTGVRS Tray System
download: view:
FTG-DTRAY3 - Typical FTGVRS Tray Connection
download: view:
FTG-DTREFL1 - Metal Edger and Wall Flashing Profiles
download: view:
FTG-DTRIR1 - Irrigation System Layout - Tubing
download: view:
FTG-DTRIR2 - Irrigation System Layout - Controls
download: view:
FTG-DTRIR3 - Irrigation Connection to Tray
download: view:
FTG-DTRIR4 - Irrigation Value Box
download: view:
FTG-DTRIR5 - Irrigation Header
download: view:
FTG-DTRW1 - Tray System at Wall
download: view:
FTG-DTRW2 - Tray System with Ballast Rock at Wall
download: view:
FTG-DTSD1 - Ballast Rock at Drain with FTVGRS Tray
download: view:
FTG-DVMW1 - Ballast Rock at Wall Termination with Vector Mapping Mesh
download: view:
FTG-DVMW2 - Wall Termination with Vector Mapping Mesh
download: view:

Hybrid Roofing System  

Das1MP - Adhered Insulation in Asphalt
download: view:
Das2MP - Adhered Insulation in FTR-601 Adhesive with SBS Base
download: view:
Das3MP - Adhered Insulation in FTR-601 Adhesive
download: view:
Das4MP - Adhered Membrane and Insulation in Asphalt - with Adhered Cover Board in Asphalt
download: view:
Das5MP - Adhered Membrane and Insulation in Asphalt with SBS Base
download: view:
Das6MP - Adhered Membrane and Insulation in FTR-601 Adhesive with SBS Base
download: view:
Das7MP - Adhered Membrane and Insulation in FTR-601 Adhesive
download: view:
Das8MP - Adhered Membrane and Insulation in Asphalt
download: view:
Das9MP - Mechanically Fastened Insulation
download: view:
Das10mp - Mechanically Fastened Cover Board and Adhered Insulation with Vapor Barrier
download: view:
Das11mp - Mechanically Fastened and Adhered Insulation with Vapor Barrier
download: view:
Das14mp - Mechanically Fastened Cover Board and Adhered Insulation
download: view:
Das15mp - Mechanically Fastened and Adhered Insulation
download: view:
Dcb1mp - Typical Multi-Ply Curb Base Termination - T-Bar Restraint
download: view:
Dd2MP - Typical Multi-Ply Scupper Flashing
download: view:
Dd3MP - Typical Multi-Ply Drain Flashing
download: view:
Dp3MP - Typical Multi-Ply Pipe Flashing
download: view:
Dp4MP - Typical Multi-Ply Field Fabricated Pipe Flashing
download: view:
Dwb1mp - Typical Multi-Ply Wall Base Termination - T-Bar Restraint
download: view:
Dwb2mp - Typical Multi-Ply Wall Base Termination - T-Bar Restraint (to FTR Fleeceback)
download: view:

Induction Welded Roofing System  

IWIA1 - Induction Weld Attachment Methods - Class Rating 1-90 and 1-135
download: view:
IWIA1a - Induction Weld Attachment Methods - Class Rating 1-90
download: view:
IWIA2 - Induction Weld Field, Perimeter, and Corner - Attachment Designations
download: view:
IWMF1 - Composite Roof Cross Section - Induction Welded System
download: view:
IWMR1 - Mechanically Fastened Induction Welded System - Over Metal Retrofit
download: view:
IWMR3 - Induction Weld Plate Attachment - Layout on Metal Retrofit
download: view:
IWS1 - FTR Induction Weld Plate and FTR Fastener - Proper Installation
download: view:
MR2 - Insulation Attachment - for Metal Retrofit
download: view:

Insulation  

D601 - FTR 601 Insulation Adhesive Application
download: view:
DI2a - Fully Adhered System (1-90 attachment) - Mechanically Attached Insulation, 2 inch Thickness or Greater
download: view:
DI4a - Fully Adhered System (1-90 attachment) - Mechanically Attached Insulation, 1.5 inch to 1.9 inch thickness
download: view:
Di1 - Preliminary Insulation Attachment for 1-90 Mechanically Attached System
download: view:
Di3 - Adhered System - Mechanically Attached Insulation, thickness less than 1.5 inch
download: view:
Di5 - Preliminary Attachment - 3-8 inch Extruded Polystyrene Cut Fold Recovery Board
download: view:
Di6-1 - Insulation-Coverboard Attachment Pattern
download: view:
FINS-90a - Class 1-90 or less M-A Insulation and Membrane Adhered - Field, Perimeter, and Corners
download: view:
FINS-90b - Class 1-90 MA Insulation and Adhered Field Membrane - with M-A Membrane in Perimeter and Corners
download: view:

Mechanically-Attached Roofing Systems - Assembly Illustrations  

Das1 - Adhered Insulation in Asphalt
download: view:
Das2 - Adhered Insulation in FTR-601 Adhesive
download: view:
Das4 - Mechanically Fastened Insulation
download: view:
Das10 - Adhered Insulation in FTR-601 Adhesive
download: view:
Das12sp - Mechanically Fastened Cover Board and Adhered Insulation
download: view:
Das13sp - Mechanically Fastened and Adhered Insulation
download: view:
Das16sp - Mechanically Fastened Cover Board and Adhered Insulation
download: view:
Das17sp - Mechanically Fastened and Adhered Inulation
download: view:
Das18sp - Mechanically Fastened and Adhered Inulation
download: view:
DBS1 - Ballasted System
download: view:
Dmfs1 - Mechanically Fastened System
download: view:

Roof Edge Systems  

De1 - Typical Edge Flashing
download: view:
De2 - 2-Piece Shop Fabricated Metal Edge Flashing
download: view:
De3 - Gutter Flashing
download: view:
De4 - FiberTite at Fascia System - Standard Fascia Edge
download: view:
De4a - FiberTite at Fascia System - Large Fascia Edge
download: view:
De5 - FiberTite at Fascia System - Raised Canted Edge
download: view:
De6 - FiberClad Metal Gravel Stop Flashing - Ballast Roofing System(s)
download: view:
De7 - Gutter Flashing - Ballast Roofing System(s)
download: view:
De8 - Architectural Metal Fascia with FiberClad Metal Cleat
download: view:
De8a - FiberTite 200 Fascia System - Raised Cleat Edge
download: view:

Simulated Metal Roofing  

SMRP - Composite Roof Cross Section - Simulated Metal Roofing Profile
download: view:
SMRP1 - Ridge and Valley Flashing - Simulated Metal Roofing Profile
download: view:
SMRP2 - Simulated Metal Rib Profile Splice - Simulated Metal Rib Profile
download: view:

Walkway and Protection Materials  

Dm1c - FTR KEE Yellow TuffTrac Walkway
download: view:
Dm1d - FTR Crossgrip Walkway - Low Wind Area
download: view:
Dm1e - FTR Crossgrip Walkway with Strapping - High Wind Area
download: view: